HOME > Power System > Measuring Instrument > Energy Meter Test Bench > Energy Meter Test Bench PTC 8320E

Energy Meter Test Bench PTC 8320E

 

Features
  • The bench accord with the standard of "IEC 60736:1982 testing equipment for electrical energy meter", "IEC 62053".
  • Close-link and ordinary calibration both can be used, ordinary calibration can be used to test single / three phase active and reactive energy meter (up to 0.5 class),close-link calibration can be used to test single / three phase active and reactive energy meter (up to 1 class).
  • The bench can test the converted quantity which is caused by negative phase, voltage unbalance, harmonic wave and so on.
  • The bench can auto-calibrate starting, no load, basic error and calibration tolerance and 24h deflection.
  • Close-link calibration is using insulate current transformer and suitable for close-link energy meter.
  • The bench is using the HC 3100 standard power meter with comparison technology to offer the test the error of energy meters.
  • The bench is using the error processor system to calculate the error of each energy meter by the sub-error system which can be connected by the internal RS485.
  • The same specification but different constant energy meter can be tested at one time.
  • For the installed pick-up equipment, can offer 3 ranges adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.
  • The bench can choose to operate by keyboard or PC which is very convenient. The working status of bench can be seen very clear and easy operation.
  • The bench is using the testing software complied with Windows 98 / 2000 / XP which can auto-testing different energy meters.
  • The software can realize the data from energy meter for statistics, search and management. It also can connect with on-line management for up load the data.
  • The energy meter hanging rack is made by Aluminum compound. The whole device configuration is a reasonable design and nice outfit.
Specification
  • Accuracy class :
    • 0.2 class (close-link calibration, the range of current : 0.25A ~ 100A)
    • 0.05 / 0.1 class (ordinary calibration)
  • Standard power testing equipment :
    • HC 3100 three phase multi-functions precision power testing instrument
    • Accuracy class : 0.05 / 0.1 class
  • Isolated current transformer equipment :
    • PTC 9503B insulate current inductance
    • Accuracy class : 0.1 (COSØ = 0.5C - 1 - 0.5L, 0.25 ~ 100A)
    • Primary current : 3 * 0.25 - 100A; Secondary current : 3 * 0.25 - 100A
    • Output power : 30VA (MAX, 100A)
  • Output voltage :
    • 3 * 57.7 / 100 / 220 / 380VY / กต; range : 0 ~ 120%
    • Fine adjustment : 0.01%
  • Output current :
    • 3 * 0.1 - 100A
    • Fine adjustment : 0.0001A (min)
  • Range of phase : 0 - 360o fine adjustment : 0.1o
  • Frequency : 45Hz - 65Hz; fine adjustment : 0.01Hz
  • Waveform distortion coefficient : voltage/ current < 0.5%
  • Output stability of voltage, current, power <0.05% (180S)
  • Output capacity (each phase) : current : 900VA (120A), voltage : 300VA (8 meters)
  • Load : capacitance, resistance, inductance (< 4µF)
  • Harmonic wave output :
    • 2-21 sub-harmonic wave, contents <40%
    • 3, 5, 7 sub-harmonic wave coupling, total content <40%
    • Phase angle control (odd sub-harmonic wave)
    • Wave group control (sub-harmonic wave)
  • Starting current output : 1mA (min), accuracy : 5%, starting power : accuracy 5%
  • Numbers of calibrated energy meter : 8 (16 on requested)
  • Testing function : Basic error test; no load test; starting test; calibration tolerance test; harmonic test
  • Input power : 3 * 220V / 380V (Y)10%, 50Hz; max. power consumption : 1800VA (8 meters)
  • Dimension :
  •