HOME > Power System > Power Transducer > Digital Power Transducer > Digital Power Transducer for Industry > Digital Power Transducer - PS Series > TST

 

 

Features
  • Linearized output
  • Outstanding CJC traceability <0.5oC < 10 minutes warm up
  • Accuracy 0.2%
  • Input/output isolation 1.6KV DC
Model & Ordering

        

Specification
  • Accuracy ( 23 + 3 oC ) :
    • 0.2% of effective range +0.5oC........J - K - E - T - N
    • 0.25% of effective range + 1.0oC.......R - S -B
  • Linearty & repeatability :
    • 0.12% tpical
    • Linearized output vs input temperature
  • Temperature stability : < 0.015% fs per oC
  • CJC stability < 0.03oC per oC......10 ~ 40oC
  • CJC traceability :
    • Warm up condition......typically
    • Less 0.5oC......10 minutes compare to 2 hours
    • Ambient temp. change......rate: 10oC / 3 minutes
    • Less 2oC deviation within 5 minutes
  • Input resistance > 20 Mega
  • Effect of wire resistance < 4 uv per 100
  • Input break detection :
    • Selectable HI-set or LO-set
    • Hi-set > 110% of rated output; LO-set < 0.5% of rated output
  • Maximum input over : < 250Vrms 30sec.
  • Power effect < 0.003% for per volt change
  • Response time & ripple : 250ms typically , ripple < 0.1% rms of span
  • Common mode rejection > 100 db 50/60 hz
  • Dielectric strength :
    • 1500Vac ..... power / input & output terminals
    • 1600Vdc ..... input / output terminals
  • Output drive capability : <10 mA for voltage modes , <10V for current mode
  • Storage condition : Temperature range -10 ~ 70oC, humidity 20~95% RH non - condensed
  • Operating condition : Temperature range -5 ~ 55oC, humidity 20~95% RH non - condensed
  • Power supply :
    • + 20% of rated , less 3.5 VA for AC input
    • + 20% of rated , less 3.5 watt for DC input
  • Construction : Socket plug - in type with barrier terminals