Specification
- Accuracy : 1% RO / 23 + 3 oC
- Input of stator :
- Effective range : 60 / 120 / 240 + 40% order on request
- Angle of conversion : Standard 330o + 30o
- Burden : < 1VA of maximum range
- Frequency : 55 - 65 Hz
- Protection : Full protection for SURGE, EMI & RFI
- Input of rotor :
- Effective range : 90 - 140 / 180 - 280V order on request
- Burden < 3.5VA
- Output ( isolated with input) :
- Range :
- Standard : DC0 - 1mA vs required rotating angle
- Option :
- DC 0 - 5 / 0 - 10 / 0 - 20 / 4 - 20mA
- DC 0 - 1 / 0 - 5 / 1 - 5 / 0 - 10 / 2 - 10V
- Drive ability : Maximum 10Kohm for 0 to 1 mA output
- > 10V for current output mode
- > 10mA for voltage output mode
- Output impedance > 30 Mega ohm
- Response time < 600 ms from 0 to 99% RO at operating
- Ripple < 0.5% P-P RO
- Long term stability < 1% RO per year
- Temperature stability < 0.1% per degree C, from 99% RO at operating
- Adjustment : Span, zero +5% / 10% ro request, zero shifter / 0 - 360o, fine / + 15o
- Protection : No damage ... open or short; full protection ... SURGE, EMI, RFI
- Magnetic effection < 0.04% at center 400 A-T / M
- Operation Condition :
- Enviroment Temperature : -5 ~ 60 oC
- Humidity : 20~99% RH non condensed
- Elevation : Under 3000 meters
- Magnetic Field : 500 A-T / M
- Waveform : Sinusoidual wave from only
- Dielectric strength : 4KV AC rms 1 minute between input / output / power / case IEC688
- Impulse Test : ANSI C37.90 / 1989, IEEE 587 / 1983, IEC 255-3, 6KV ( 1.2 * 50us), 3KA (8 * 20us)... current only
- Surge Test (ring wave) : IEEE 587 / 1983 (3KV - 0.5 us / 100 KHz), IEC255-3 (2.5KV - 0.25ms / 1MHz)
|
|