HOME > Power System > Power Transducer > Digital Power Transducer > Digital Power Transducer for Industry > Digital Power Transducer - PS Series > PSR

 

 

Features
  • Linearized output
  • Field - rangeable :
    • Switchable input & output ranges
    • Changeable input T/C module P1 / P4 / P8 / C4
  • Accuracy 0.15%
  • Input / output isolation 1.6KVdc
  • Available standard calibration or custom calibration
Model & Ordering

        

Specification
  • Accuracy ( 23 + 3 oC ) :
    • 0.15% of effective range + 0.3oC..... P4 / P8
    • 0.25% of effective range + 0.15oC ..... P1 / CU
  • Linearty & repeatability : 0.1% typical
  • Temperature stability < 0.01% fs per degree C
  • Configuration :
    • Three wires connection / applicable for two wires
    • Excitation ... 5 mAdc constant current soure
    • Change input module
  • Field rangeability :
    • Selectable output mode.....voltage or current
    • Switchable input ranges/switchable output ranges
    • Switchable AC power 120V or 240V
    • selectable oC / oF calibration
  • Effect of wire resistance :
    • Automatically eliminated for 3 wires connection
    • Offset recal. required for 2 wires connection
  • Input break detection : Hi - set >110% of rated output
  • Maximum input over : <250 Vrms 30 sec.
  • Power effect < 0.003% for per volt change
  • Response time & ripple : 250ms typically , ripple < 0.1% rms of span
  • Output drive capability <10mA for voltage mode, <10 V for current mode
  • Common mode rejection > 100db, 50 / 60 Hz
  • Dielectric strength :
    • 1500Vac ..... power / input & output terminals
    • 1600Vdc ..... input / output terminals
  • Storage condition : Temperature range -10 ~ 70oC, humidity 20~95% RH non - condensed
  • Operating condition : Temperature range -5 ~ 55oC, humidity 20~95% RH non - condensed
  • Power supply :
    • + 20% of rated , less 3.5 VA for AC input
    • + 20% of rated , less 3.5 watt for DC input
  • Construction : Socket plug - in type with barrier terminals