Features
- Top changer & position application
- Field - rangeability : Switchable input & output ranges
- Accuracy 0.1%
- Input / output isolation 1.6KVdc
- Available standard calibration or custom calibration
|
|
Model & Ordering
 |
|
Specification
- Accuracy ( 23 + 3 oC ) :
- 0.1% of effective range
- 0.15% of effective range of < 50
input span
- Linearty & repeatability : 0.05% typical
- Temperature stability < 0.008% ro per degree C
- Configuration :
- Two wires or three wires connection
- Excitation 2 / 0.2 mAdc constant current source
- Field rangeability :
- Selectable output mode ..... voltage or current
- Switchable input range / switchable output range
- Switchable AC power 120V or 240V
- Effect of wire resistance :
- Automatically eliminated for 3 wires connection
- offset recal. required for 2 wires connection
- Power effect < 0.003% for per volt change
- Response time & ripple : 400ms typically , ripple < 0.1% rms of span
- Output drive capability <10mA for voltage mode, <10 V for current mode
- Common mode rejection > 80db, 50 / 60 Hz
- Dielectric strength :
- 1500Vac ..... power / input & output terminals
- 1600Vdc ..... input / output terminals
- Output drive capability < 10 mA for voltage mode , < 10V for current mode
- Storage condition : Temperature range -10 ~ 70oC, humidity 20~95% RH non - condensed
- Operating condition : Temperature range -5 ~ 55oC, humidity 20~95% RH non - condensed
- Power supply :
- + 20% of rated , less 3.5 VA for AC input
- + 20% of rated , less 3.5 watt for DC input
- Construction : Socket plug - in type with barrier terminals
|
|