Features
  • Top changer & position application
  • Field - rangeability : Switchable input & output ranges
  • Accuracy 0.1%
  • Input / output isolation 1.6KVdc
  • Available standard calibration or custom calibration
Model & Ordering

        

Specification
  • Accuracy ( 23 + 3 oC ) :
    • 0.1% of effective range
    • 0.15% of effective range of < 50 input span
  • Linearty & repeatability : 0.05% typical
  • Temperature stability < 0.008% ro per degree C
  • Configuration :
    • Two wires or three wires connection
    • Excitation 2 / 0.2 mAdc constant current source
  • Field rangeability :
    • Selectable output mode ..... voltage or current
    • Switchable input range / switchable output range
    • Switchable AC power 120V or 240V
  • Effect of wire resistance :
    • Automatically eliminated for 3 wires connection
    • offset recal. required for 2 wires connection
  • Power effect < 0.003% for per volt change
  • Response time & ripple : 400ms typically , ripple < 0.1% rms of span
  • Output drive capability <10mA for voltage mode, <10 V for current mode
  • Common mode rejection > 80db, 50 / 60 Hz
  • Dielectric strength :
    • 1500Vac ..... power / input & output terminals
    • 1600Vdc ..... input / output terminals
  • Output drive capability < 10 mA for voltage mode , < 10V for current mode
  • Storage condition : Temperature range -10 ~ 70oC, humidity 20~95% RH non - condensed
  • Operating condition : Temperature range -5 ~ 55oC, humidity 20~95% RH non - condensed
  • Power supply :
    • + 20% of rated , less 3.5 VA for AC input
    • + 20% of rated , less 3.5 watt for DC input
  • Construction : Socket plug - in type with barrier terminals