Features
- Wide switchable input ranges 0 to 10 ~ 10 KHZ
- Wide switchable output ranges
- With discriminator - adjustable input sensitivity
- With intensed filter-selectable
- F-V / crystal heart conversion long term stability guaranteed
- 0.1% accuracy
|
|
Model & Ordering
 |
|
Specification
- Accuracy ( 23 + 3 oC ) : 0.1% of rated output
- Linearty & repeatability : 0.05% typical
- Temperature stability < 0.008% of range per oC
- Configuration :
- Switchable input ranges; switchable output ranges
- +5% adjustability.....fine span & zero
- Power effect < 0.003% for per volt change
- Response time :
- < 800ms typical........non intensed filter on
- < 4 seconds..............intensed filter on
- < 0.05% / Fin ( Fin.......unit khz )
- Input sensing :
- Input types
- Voltage.........unipolar / bipolar
- Signal ...........square pulse or sinusoidal signal, open collector
- Sensitivity.......10 mV to 5V adjustable; 1 V at factory calibration
- Maximum over........100 V continuous.....400V 1 sec
- Excitation : +12 VDC, drive capability 20 mA maximum
- Output drive <10mA for voltage mode, <10 V for current mode
- Dielectric strength :
- 1500Vac ..... power / input & output terminals
- 1600Vdc ..... input / output terminals
- Operating condition : Temperature range -5 ~ 55oC, humidity 20~95% RH non - condensed
- Storage condition : Temperature range -10 ~ 70oC, humidity 20~95% RH non - condensed
- Power supply :
- + 20% of rated , less 3.5 VA for AC input
- + 20% of rated , less 3.5 watt for DC input
- Construction : Socket plug - in type with barrier terminals
|
|