Model & Ordering

      

Specification
  • Accuracy ( 23 + 5 oC ) : 0.1% RO
  • Linearty & repeatability : 0.05% typical
  • Temperature stability : Less 0.007% ro per degree C effective range
  • Configuration ( Field rangeability ) :
    • Exciting DC constant 2.5V
    • Switchable of input ranges & output ranges
  • Input break detection : Hi-set > 110% of rated output
  • Power effect : Less 0.003% for per volt change
  • Output drive capability : Maximum 10mA for voltage mode, maximum 10V for current mode
  • Response time & ripple : Less 400ms typically, ripple less 0.1% rms of span
  • Common mode rejection > 100db DC to 60Hz
  • Dielectric strength : 4KV rms AC between input / output / power / case
  • Impulse & surge test : IEEE 587 / 1983 or IEC 255-3
  • Storage condition : Temperature range -25 to +70oC, RH 20 to 95% non condensed
  • Operating condition : Temperature range -20 to +65oC, RH 20 to 95% non condensed
  • Power supply : +20% of rating, < 3.5VA
  • Dimension : W*H*D : 12T (60.6mm) * 3U (128.5mm) * 238mm